DFV24ENGINEERING TOOLSDownload ↗

USR-GPRS232-730 / DFV24 TOOLS

Set up your modem.
Check the connection.

TCP connection configurator and tester for USR-GPRS232-730. From the local COM port to the first response from your server.

Windows · Linux · macOS28 build platforms
USR / GPRS232-730HARDWARE
Modem USR-GPRS232-730, connectors RS-232, RS-485, SIM, antenna and power

Serial port → mobile network

Socket A · NET / TCP
$ go run .
+ Вход в командный режим
+ Настройка TCP-соединения
+ Сохранение конфигурации
✓ Параметры Socket A подтверждены
Setting sequence example
Local UART115200 · 8N1Permanent connectionSocket A · longTransparent transmissionCR / LF / CRLF

FROM PORT TO SERVER

One understandable
data path.

The computer transmits bytes to the modem via RS-232.
The modem connects to the server through the operator's network.

ComputerCOM port→USB–RS-232Local UART→USR-GPRS232-730SIM + APN→TCP serverSocket A
Connecting equipment ↗

DFV24 TOOLS

Setup.
Diagnostics. Exchange.

Choose a tool for the task.
The interface works directly in the terminal.

CONFIGURATION/AT

Configurator

Sets Socket A parameters and checks them after saving in the modem.

  • Selecting COM port and UART
  • Explicit confirmation of entry
  • Control reading after restart
Configurator setup log
DIAGNOSTICS / TCP

Communication tester

Checks the modem status and two-way communication with your server.

  • SIM, GSM signal, APN and local IP
  • Checking Socket A and Connected
  • Send text and log responses
Modem diagnostic results

CONFIGURATOR GUIDE

Set up the modem COM → NET → Socket A

3. Configurator: connection setup

The configurator switches the modem to mode NET, sets the TCP address of Socket A, enables it and selects a persistent connection long. After saving, the program reads these parameters again.

Step 1: Select COM Port and UART

Configurator: serial port selection

  1. In the System Ports line, select the adapter.
  2. Make sure its name appears in the Port Name field. If necessary, enter the name manually.
  3. Select the UART speed and format appropriate current modem settings.
  4. Click Next.

If the adapter is connected after startup, click “Update ports”. If the list is not available, manual entry can be used.

The default values ​​are 115200 baud and 8N1: 8 data bits, no parity, 1 stop bit. These are the starting values ​​of the interface, and not the result of automatic UART detection.

Field What does it mean
Speed, baud Communication speed between computer and modem
Data bits 7 or 8 bit
Parity N/E/O No parity / even / odd
Stop bits 1 or 2

Changing these fields configures the computer's local port. The configurator does not reprogram the UART inside the modem.

Step 2: Enter the server

Configurator: TCP server address and port

In the "IPv4 or DNS" field, enter only the address: for example, DNS name server.example.com. In a separate field, specify the TCP port and click “Next”.

An IPv4 or ASCII DNS name up to 100 bytes long and a port from 1 to 65535 are allowed. Do not add http://, https://, path, spaces inside the address or port after the colon. IPv6 is not supported.

If there is an input error, a message will appear below the form. Correct the value and click Next again. No AT commands are sent until the entry is confirmed.

Step 3: Confirm your entry

Configurator: confirmation of entry

Check COM port, UART, target address and TCP port. The summary must indicate NET / TCP, Socket A and persistent connection.

“Back” returns to the server form. “Record” starts working with the modem. After confirmation, wait until it is finished and do not disconnect the power or cable.

Step 4. Check the result

Configurator: successful save and test read

The log sequentially appears opening the port, entering command mode, firmware version, setting parameters, saving and control reading.

The inscription “Control reading confirmed the parameters of Socket A” means that the settings read after saving coincide with the selected ones. The connection via the mobile network is checked separately in the tester and on the server.

If the settings already match, the program reports that the entry has been skipped. Repeated saving and restarting are not performed in this branch.

After the result, click "Back" to set up another device or "Exit" to end the application. The serial port is closed after the script completes, even before the log screen closes.

If setup fails

Message or stage What to do
Failed to open port Check the number, connection, driver and other programs occupying the port
Error entering AT mode Check UART, power, cable and RS-232 pinout
Error reading version or settings Save the log and firmware version, check AT protocol compliance
Recording interrupted before saving Restart the modem before trying again: some of the time parameters may have changed
Save not confirmed Restart the modem and check the settings again: the saving result is unknown
Save confirmed, control failed Wait for startup and check again; this is not the same as saving
The read parameters are different Record the actual values ​​and do not consider the setting complete

If the change command fails, the program stops recording and does not send AT+S. Built-in log shows steps and errors; There is no button to export the log to a file.

DOCX manual (Russian) ↓

TESTER GUIDE

Check and transfer data Diagnostics → TCP → Message

4. Tester: diagnostics and messaging

The current version of the tester consists of three steps: diagnostic parameters, results and exchange. It reads the modem's state via AT commands, returns it to transparent mode and then transmits messages. The tester does not record Socket A settings.

Step 1: Specify the port and expected server

Tester: COM port, server and UART

  1. Select the COM port or enter it manually.
  2. Enter the server and TCP port that should be configured in Socket A.
  3. Select the current modem UART.
  4. Click “Connect” and wait for diagnostic results.

The address in this form specifies expected configuration for comparison. If a different server is specified in the modem, the tester will show a mismatch. To change the server, use the configurator.

The full diagnostic runs with a total context of 35 seconds. During the test, the application enters AT mode, reads the parameters sequentially, then sends a return command AT+ENTM.

Step 2: Read the diagnostic results

Tester: results of testing modem subsystems

Verification What does it show
RS-232 / AT The modem responds and the command mode is entered
Modem UART Read speed, format and flow control
Firmware Firmware version
Modem (IMEI) Modem ID
SIM card (ICCID) SIM ID
GSM signal RSSI, approximate dBm level and BER
APN Name of the recorded APN; login and password are not displayed
GPRS / local IP IPv4 issued to the modem, if received
Operating mode Expected NET
Socket A Protocol, actual address and port, comparison with form
Socket A enabled Expected SOCKAEN=on
Socket A mode long or short
TCP connection Current value SOCKALK=Connected or Disconnected
Transparent mode Is the return confirmed? AT+ENTM

The marks on the left mean: [ OK ] - check is successful, [ ! ] - warning, [СБОЙ] — verification error. A weak signal may require inspection of the antenna, location and coverage. The presence of an APN string does not confirm that the APN is correct for the operator.

Navigation to messages is allowed if confirmed NET, TCP, address and port match, Socket A enabled, status Connected and successful completion of the diagnostic script. The remaining lines must be evaluated separately: even with the exchange button available, the report may contain warnings or failures of auxiliary checks.

“Start Exchange” opens the third step. If you refuse, use “Retry” or “Back”: the program returns to the form where you can check the parameters and click “Connect” again.

Connected reflects the status read during diagnosis. There is no constant connection polling during the exchange. To check again, disconnect and connect again.

Step 3: Enter a message

Tester: entering a message to send to the server

After entering the exchange, the top line confirms the diagnostic result and returns to transparent mode. Enter a message in the Message field. The picture shows a test text string.

Select the ending that matches the server protocol:

End What is added
Without ending Entered text only
CR Byte 0x0D
LF Byte 0x0A
CRLF Bytes 0x0D 0x0A

In the current interface, the ending selection is located under the message field. If it or the buttons are hidden due to the height of the window, enlarge the terminal and navigate through the elements with the key Tab. The pictures shown were taken with a limited terminal height, so part of the form may be scrolled.

The text is transmitted in UTF-8. The limit for one message is 16384 bytes including the ending. The number of bytes may differ from the number of characters: Russian letters take up more than one byte. An empty message can only be sent with the selected ending.

Sequence \n, typed manually, is two characters. To send a line feed, select LF in the list of endings.

Submit and check the log

Tester: message sent to serial port

Click "Submit". The field is cleared, and after a successful entry, a line with an arrow appears in the log → and status with the number of bytes transferred. If there is an error, the program reports it below; if the field is left empty, the entered text is restored.

The status “Transferred ... bytes” confirms writing to the local serial port. Check the delivery and processing of the message in the server log or in the application protocol response.

Get the answer

Tester: received server data

The reception works in the background. Arrow ← means data received from the modem. In quotes, control bytes are shown escaped: for example, "\n" — line feed. The picture shows the following incoming data; they do not by themselves confirm that the application response to the test string is correct.

One response can come in several log lines, and several responses can come in one block. TCP and serial port transmit a stream of bytes; The message boundaries are determined by your server's protocol.

Complete the exchange

“Disable” stops reception, closes the COM port and returns to the connection form. “Exit” closes the port and application. Esc on the exchange screen disables the local port.

Closing the COM port by the tester is not a command to terminate the TCP connection of the modem: when Socket A is enabled, the modem continues to work independently.

If there is a reception error, the log reports it, and the status suggests disconnecting and reopening the port. There is no automatic reconnection of the tester.

DOCX manual (Russian) ↓

EQUIPMENT

Bridge between
device and network.

USR-GPRS232-730 transmits serial device data via GSM/GPRS. Prepare SIM, antenna, power, APN and an available TCP server.

Connecting a computer, modem, power and antenna

Device characteristics

NetGSM / GPRS / EDGE 850 / 900 / 1800 / 1900 MHz
InterfacesRS-232 / RS-485 SMA antenna SIM card
UART2400–921600 baud according to the modem directory
ProtocolsTCP / UDP / DNS / HTTP, by mode
Power supply9–24 V DC according to the Russian edition 2025. Check the markings and the passport revision.
Case and temperature80 × 84 × 25 mm −25…+85 °C according to Russian edition 2025

The power ranges in documents of different versions differ. Source of characteristics PDF ↗

KNOWLEDGE BASE

Everything for work
with a modem.

Instructions, commands and diagrams.
Read here or save the document.

Complete User Guide

USR-GPRS232-730 User Manual

From modem connection to two-way exchange with TCP server

Practical instructions for the operator: equipment preparation, Socket A configuration, communication diagnostics, message transmission and error recovery.

Navigation

The full catalog of 67 commands in the model reference book is included in AT_COMMANDS.md. The commands necessary for normal work with the two programs are discussed in detail below.

The kit includes two programs: configurator specifies the parameters of a persistent TCP connection, and tester diagnoses the modem and allows you to send messages to the server. Both programs run in a terminal and support keyboard and mouse.

This manual describes the current implementation of the programs. Illustrations made in Windows Terminal; The design in another terminal may be different. Server addresses, ports, and device identifiers are obscured in the images. Snapshots reflect individual sessions: firmware versions, COM ports, and results shown are not universal values ​​for all modems.

Images processed for publication using image_gen; processing features are described in images/README.md. They explain the layout of interface elements and do not replace the original test log.

1. Preparation of the workplace

You will need a USR-GPRS232-730 modem with power and antenna, a SIM card with network access, a USB-RS-232 adapter and an available TCP server. The APN must be configured in advance according to the SIM card. A regular USB to TTL adapter without level matching does not replace RS-232.

Connect the adapter to the RS-232 connector of the modem and to the computer. Turn on the power and wait for it to boot. In Windows Device Manager, find the COM port number assigned to the adapter. On Linux the name usually looks like /dev/ttyUSB0 or /dev/ttyACM0.

Close other applications using this port. Launch the configurator and tester sequentially: two applications will not be able to simultaneously own the same COM port.

Have the following information ready:

What you need to know Example or explanation
Serial port COM3; the actual number depends on the computer
Current UART parameters of the modem For example, 115200 baud, 8 bits, N, 1 stop bit
TCP server Working IPv4 or ASCII DNS name
TCP port A number from 1 to 65535 on which the server is listening
APN The APN of your SIM card is already recorded in the modem

Address 198.51.100.73 and port 34827, found in the project examples, serve as a filler example. The address is reserved for documentation. When working, indicate your available server.

2. Launching programs

Ready Windows files

Open PowerShell or Windows Terminal in your programs directory. In a set of assemblies for a specific platform, the files are called:

.\gprs232-730.exe
.\gprs232-730-test.exe

In the catalog dist/ there may also be assemblies with the full platform name:

.\dist\gprs232-730-windows-amd64.exe
.\dist\gprs232-730-test-windows-amd64.exe

For regular 64-bit Windows on Intel/AMD, choose windows-amd64, for Windows ARM - windows-arm64. Go installed is not required for the finished binary. The USB–RS-232 driver must be installed.

From source code

Requires Go 1.25 or later. From the project root, run one of the commands:

go run .
go run ./app-test

Open a fairly high terminal window: this is especially important for the tester form with UART parameters and the diagnostics page. If the bottom buttons are not visible, enlarge the window or reduce the font size.

General management

Action How to do it
Move to next field or button Tab
Return to previous element Shift+Tab
Select list value Open list and use arrows, confirm Enter
Press the button Select it and click Enter or click the mouse
Go back Esc, if the operation is not currently running
Quit the application "Exit" or Ctrl+Cwhen the operation is completed

A tooltip at the bottom of each screen shows the available actions. When recording, diagnosing and sending, wait for the result: navigation and normal exit are temporarily blocked.

3. Configurator: connection setup

The configurator switches the modem to mode NET, sets the TCP address of Socket A, enables it and selects a persistent connection long. After saving, the program reads these parameters again.

Step 1: Select COM Port and UART

Configurator: serial port selection

  1. In the System Ports line, select the adapter.
  2. Make sure its name appears in the Port Name field. If necessary, enter the name manually.
  3. Select the UART speed and format appropriate current modem settings.
  4. Click Next.

If the adapter is connected after startup, click “Update ports”. If the list is not available, manual entry can be used.

The default values ​​are 115200 baud and 8N1: 8 data bits, no parity, 1 stop bit. These are the starting values ​​of the interface, and not the result of automatic UART detection.

Field What does it mean
Speed, baud Communication speed between computer and modem
Data bits 7 or 8 bit
Parity N/E/O No parity / even / odd
Stop bits 1 or 2

Changing these fields configures the computer's local port. The configurator does not reprogram the UART inside the modem.

Step 2: Enter the server

Configurator: TCP server address and port

In the "IPv4 or DNS" field, enter only the address: for example, DNS name server.example.com. In a separate field, specify the TCP port and click “Next”.

An IPv4 or ASCII DNS name up to 100 bytes long and a port from 1 to 65535 are allowed. Do not add http://, https://, path, spaces inside the address or port after the colon. IPv6 is not supported.

If there is an input error, a message will appear below the form. Correct the value and click Next again. No AT commands are sent until the entry is confirmed.

Step 3: Confirm your entry

Configurator: confirmation of entry

Check COM port, UART, target address and TCP port. The summary must indicate NET / TCP, Socket A and persistent connection.

“Back” returns to the server form. “Record” starts working with the modem. After confirmation, wait until it is finished and do not disconnect the power or cable.

Step 4. Check the result

Configurator: successful save and test read

The log sequentially appears opening the port, entering command mode, firmware version, setting parameters, saving and control reading.

The inscription “Control reading confirmed the parameters of Socket A” means that the settings read after saving coincide with the selected ones. The connection via the mobile network is checked separately in the tester and on the server.

If the settings already match, the program reports that the entry has been skipped. Repeated saving and restarting are not performed in this branch.

After the result, click "Back" to set up another device or "Exit" to end the application. The serial port is closed after the script completes, even before the log screen closes.

If setup fails

Message or stage What to do
Failed to open port Check the number, connection, driver and other programs occupying the port
Error entering AT mode Check UART, power, cable and RS-232 pinout
Error reading version or settings Save the log and firmware version, check AT protocol compliance
Recording interrupted before saving Restart the modem before trying again: some of the time parameters may have changed
Save not confirmed Restart the modem and check the settings again: the saving result is unknown
Save confirmed, control failed Wait for startup and check again; this is not the same as saving
The read parameters are different Record the actual values ​​and do not consider the setting complete

If the change command fails, the program stops recording and does not send AT+S. Built-in log shows steps and errors; There is no button to export the log to a file.

4. Tester: diagnostics and messaging

The current version of the tester consists of three steps: diagnostic parameters, results and exchange. It reads the modem's state via AT commands, returns it to transparent mode and then transmits messages. The tester does not record Socket A settings.

Step 1: Specify the port and expected server

Tester: COM port, server and UART

  1. Select the COM port or enter it manually.
  2. Enter the server and TCP port that should be configured in Socket A.
  3. Select the current modem UART.
  4. Click “Connect” and wait for diagnostic results.

The address in this form specifies expected configuration for comparison. If a different server is specified in the modem, the tester will show a mismatch. To change the server, use the configurator.

The full diagnostic runs with a total context of 35 seconds. During the test, the application enters AT mode, reads the parameters sequentially, then sends a return command AT+ENTM.

Step 2: Read the diagnostic results

Tester: results of testing modem subsystems

Verification What does it show
RS-232 / AT The modem responds and the command mode is entered
Modem UART Read speed, format and flow control
Firmware Firmware version
Modem (IMEI) Modem ID
SIM card (ICCID) SIM ID
GSM signal RSSI, approximate dBm level and BER
APN Name of the recorded APN; login and password are not displayed
GPRS / local IP IPv4 issued to the modem, if received
Operating mode Expected NET
Socket A Protocol, actual address and port, comparison with form
Socket A enabled Expected SOCKAEN=on
Socket A mode long or short
TCP connection Current value SOCKALK=Connected or Disconnected
Transparent mode Is the return confirmed? AT+ENTM

The marks on the left mean: [ OK ] - check is successful, [ ! ] - warning, [СБОЙ] — verification error. A weak signal may require inspection of the antenna, location and coverage. The presence of an APN string does not confirm that the APN is correct for the operator.

Navigation to messages is allowed if confirmed NET, TCP, address and port match, Socket A enabled, status Connected and successful completion of the diagnostic script. The remaining lines must be evaluated separately: even with the exchange button available, the report may contain warnings or failures of auxiliary checks.

“Start Exchange” opens the third step. If you refuse, use “Retry” or “Back”: the program returns to the form where you can check the parameters and click “Connect” again.

Connected reflects the status read during diagnosis. There is no constant connection polling during the exchange. To check again, disconnect and connect again.

Step 3: Enter a message

Tester: entering a message to send to the server

After entering the exchange, the top line confirms the diagnostic result and returns to transparent mode. Enter a message in the Message field. The picture shows a test text string.

Select the ending that matches the server protocol:

End What is added
Without ending Entered text only
CR Byte 0x0D
LF Byte 0x0A
CRLF Bytes 0x0D 0x0A

In the current interface, the ending selection is located under the message field. If it or the buttons are hidden due to the height of the window, enlarge the terminal and navigate through the elements with the key Tab. The pictures shown were taken with a limited terminal height, so part of the form may be scrolled.

The text is transmitted in UTF-8. The limit for one message is 16384 bytes including the ending. The number of bytes may differ from the number of characters: Russian letters take up more than one byte. An empty message can only be sent with the selected ending.

Sequence \n, typed manually, is two characters. To send a line feed, select LF in the list of endings.

Submit and check the log

Tester: message sent to serial port

Click "Submit". The field is cleared, and after a successful entry, a line with an arrow appears in the log → and status with the number of bytes transferred. If there is an error, the program reports it below; if the field is left empty, the entered text is restored.

The status “Transferred ... bytes” confirms writing to the local serial port. Check the delivery and processing of the message in the server log or in the application protocol response.

Get the answer

Tester: received server data

The reception works in the background. Arrow ← means data received from the modem. In quotes, control bytes are shown escaped: for example, "\n" — line feed. The picture shows the following incoming data; they do not by themselves confirm that the application response to the test string is correct.

One response can come in several log lines, and several responses can come in one block. TCP and serial port transmit a stream of bytes; The message boundaries are determined by your server's protocol.

Complete the exchange

“Disable” stops reception, closes the COM port and returns to the connection form. “Exit” closes the port and application. Esc on the exchange screen disables the local port.

Closing the COM port by the tester is not a command to terminate the TCP connection of the modem: when Socket A is enabled, the modem continues to work independently.

If there is a reception error, the log reports it, and the status suggests disconnecting and reopening the port. There is no automatic reconnection of the tester.

5. Recommended test sequence

  1. Start the TCP server and enable logging of new connections and received data.
  2. Prepare the SIM card, APN, power and antenna of the modem.
  3. Use the configurator to specify the server and receive confirmation of the control reading.
  4. Exit the configurator or wait until the script that releases the COM port finishes.
  5. In the tester, set the same server, port and UART.
  6. Run diagnostics and check the actual Socket A and Connected.
  7. Pass a unique string and check its bytes on the server.
  8. Send the server a response over the same connection and find it in the tester log.
  9. Record the result and exit the tester via “Disable” or “Exit”.

Successful configuration, TCP status, and successful application exchange are three separate results. Checking one does not replace the others.

6. Frequent difficulties

Symptom Check and action
Port not found Reconnect the adapter, refresh the list, check the driver, enter the name manually
Access denied or port busy Close other instances and proprietary utilities; on Linux check your permissions
No response AT Check UART, port, power and RS-232 cable
Socket A points to a different address Write the required server with the configurator or correct the expected tester data
SOCKALK=Disconnected Check APN, SIM, signal, server availability and firewall, then repeat diagnostics
Low RSSI Check the antenna and reception conditions, compare with the modem indication
Server connected, no response Check message format, encoding and required line ending
The message is visible in the log only with an arrow → Check receipt on server: this arrow reflects local sending
Buttons are not visible Increase terminal height or decrease font, use Tab
Error after saving Distinguish undefined save from test read error by log text

The interface does not have settings for APN, UART of the modem itself, and application protocol. For investigation, save the firmware version, UART, error text, Socket A status and the corresponding fragment of the server log.

7. Posting screenshots

In published illustrations, addresses and ports are obscured by solid, opaque areas. IMEI, ICCID and local IP are also hidden in the diagnostics; in the terminal header - the path with the user name. Signatures and check results are saved.

Apps do not retouch their screens themselves; please make sure to close this information separately before sending new photos to third parties. The APN login and password in the regular diagnostic line are already hidden by the tester.

For more technical details, build commands, and limitations, see README.md, requirements - in TECHNICAL_SPEC.md.

8. How communication via a modem works

8.1. Data Path

Data transmission scheme: terminal, modem, operator network and server

Figure from the Russian edition of the 2025 manual, page 6; this illustration is presented in the project's knowledge base.

The computer transmits bytes via USB–RS-232. The modem receives them via UART, uses the SIM card to access the mobile network and forwards them via TCP to the server. The answer goes the same way in the opposite direction.

The modem initiates an outgoing connection. The server must listen to the port, and its address must be accessible from the operator's network. The public address of the modem itself is usually not required for this scenario. Address localhost, address 127.0.0.1 and the address of a computer in a closed home network do not automatically indicate a server accessible to the modem: appropriate routing, VPN or server publication is needed.

There are two different ports here:

Term Meaning Example
COM port Computer local serial interface COM3
TCP port Network service number on the server Number from 1 to 65535

Changing the TCP port does not change the COM port and UART. The 115200 baud rate specifies local serial traffic, not the guaranteed speed of the mobile network.

8.2. Connectors and connection order

Connectors RS-232, RS-485, power, SIM card and antenna

The location of the connectors is from the Russian edition of the manual 2025, page 8. Check the markings with your version of the device.

  1. Turn off power before installing or rewiring.
  2. Install the SIM card and connect the antenna.
  3. Connect the RS-232 modem to the USB to RS-232 adapter and the computer.
  4. Apply power through the input provided for your instance. The Russian edition specifies a range of 9–24 VDC; Check housing markings and polarity. Do not use two power inputs at the same time.
  5. Wait for it to download, then open the COM port in the program.

An example of connecting a modem to a computer, antenna and power

Hardware connection from the Russian edition of the 2025 manual, page 6. The figure shows the available interfaces; For the described programs, local RS-232 is used; connecting RS-232 and RS-485 at the same time for configuration is not required.

Evaluate power, operation and network indications along with diagnostics. One lit indicator does not confirm data delivery to the server. The exact flashing modes depend on the design and firmware; These instructions do not replace the device data sheet.

8.3. Command and transparent modes

Functional diagram: transparent transmission, SMS, HTTPD and configuration

Functional diagram from the Russian edition of the 2025 manual, page 9. The capabilities of the entire modem are wider than the capabilities of the two project programs.

In transparent mode, the text in the message field becomes data for the server. In command mode, the modem perceives AT commands as instructions: reads parameters, changes settings and responds OK or a mistake.

Both programs manage transitions themselves. The configurator enters AT mode, reads and changes four parameters, saves, checks and exits. The tester enters for diagnostics, returns through AT+ENTM and only then allows the exchange of messages.

Do not use the Message field as a modem configuration console. In the current scenario, this field is for application text; There is no separate manual AT terminal in the programs.

8.4. APN, Socket A and service packets

APN determines the SIM card's access to the data network. The APN name and the need for a login and password are confirmed with your telecom operator. The tester shows the recorded APN, but does not check the tariff, balance and permission of the data service.

Socket A is the logical network connection of the modem. This is not a physical RS-232 connector. Settings TCP, address, port, on And long describe where the modem connects and how it maintains the connection.

The modem can transmit registration and heartbeat packets if they are enabled in the existing configuration. The server needs to take them into account in its protocol. Data appearing without clicking Submit is not necessarily an error: it could be incoming traffic or a configured service transfer.

The configurator does not change APN, modem UART, Socket B, registration packets and heartbeat. Their configuration requires a separate decision from the operator and the service utility or terminal.

9. Button directory

Configurator

Where Button Result
Port and UART "Next" Checks local settings and opens server form
Port and UART "Update ports" Rereads the list, saving the selected UART parameters
Port and UART "Exit" Ends the program
Server "Next" Checks the address/port and shows a summary
Server "Back" Returns to port selection
Confirmation "Back" Returns to server form without entry
Confirmation "Record" Opens a port and runs an AT script
Result "To the beginning" Shows the initial screen for the next session
Result "Exit" Ends the program

Entering the address and port is fixed when you click “Next”. If you leave the form early, the input that has not yet been confirmed may not be saved. After “Record”, wait for the result; the available buttons will appear at the end of the scenario.

Tester

Where Button Result
Options "Connect" Opens a COM port and runs diagnostics on the specified server
Options "Update ports" Rereads the list of serial ports
Options "Exit" Ends the application
Successful diagnosis "Start exchange" Opens the message form
Unsuccessful diagnosis "Repeat" Returns to options; for a new check, click “Connect”
Diagnostics "Back" Closes the local connection and returns to the form
Diagnostics "Exit" Closes the port and application
Exchange "Send" Sends text and the selected ending to the modem
Exchange "Disable" Stops receiving, closes the COM port and returns to the form
Exchange "Exit" Closes the port and ends the program

After changing the server fields, run Connect to apply them to the new diagnostic. The update ports button is not a confirmation of the new server address.

10. AT commands and manual diagnostics

10.1. How to read examples

AT+ИМЯ? usually asks for a value, AT+ИМЯ=... asks him AT+ИМЯ=? prompts for valid parameters if the command supports it. For a number of queries, the directory also allows a form without ?. Use the option given for the specific command.

CR - one byte 0x0D, the end of a normal AT command. Inscriptions <адрес>, <порт> And <APN> — explanatory notations: angle brackets are not transmitted. Quotes in commands are regular ASCII ", and not typographic “Christmas trees”.

In the examples below, line breaks show the structure of the dialogue. The program sends regular commands with CR, and the answers may contain CR/LF. Login Sequences +++ And a are transmitted without line ending.

10.2. Entry and exit

Step Action Answer
1 Maintain a pause without transmission for at least 200 ms; applications use 350 ms —
2 Transmit +++ without CR/LF a
3 Having received a, transfer immediately a no CR/LF, within 3 seconds +ok
4 Send AT commands one at a time, waiting for the response to complete Data field and OK or error
5 Transmit AT+ENTM with CR OK, return to operating mode

For manual checking, use a separate serial terminal and first close the project applications. Do not send the entire sequence in one insert: modem responses and pauses between stages are important.

10.3. All commands used by applications

Command Purpose and expected data Who uses
AT+VER? Version: +VER:..., then OK Both programs
AT+WKMOD? Working mode: +WKMOD:NET for our scenario Both
AT+SOCKA? Protocol, address and port: +SOCKA:"TCP","server.example",34827 Both
AT+SOCKAEN? Activity: +SOCKAEN:on or off Both
AT+SOCKASL? Connection type: +SOCKASL:long or short Both
AT+WKMOD="NET" Selects transparent network transmission; expected OK Configurator, if the mode is different
AT+SOCKA="TCP","server.example",34827 Specifies the TCP server Socket A; expected OK Configurator, if the address/protocol/port is different
AT+SOCKAEN="on" Includes Socket A; expected OK Configurator if the socket is disabled
AT+SOCKASL="long" Selects a permanent connection; expected OK Configurator, if available short
AT+S Saves the current settings and restarts the modem; expected OK Configurator after confirming changes
AT+ENTM Exits command mode; expected OK Both
AT+UART? +UART:baud,parity,data,stop,flow Tester
AT+IMEI? +IMEI:..., modem ID Tester
AT+ICCID? +ICCID:..., SIM ID Tester
AT+CSQ +CSQ:rssi,ber, signal quality Tester
AT+APN? +APN:"имя","логин","пароль" Tester; shows the name in the report, hiding credentials
AT+CIP? +CIP: and strings SOCKET:IP Tester
AT+SOCKALK? +SOCKALK:Connected or Disconnected Tester

Each request is considered successful only after the completion OK. Having the required field without final confirmation does not complete the exchange successfully.

10.4. Example of a complete setup script

Below is a list of commands for the case when all four parameters are different. The real server input is done in the form; the example is not a ready-made configuration of your object.

Вход: +++ → a → a → +ok

AT+VER?
AT+WKMOD?
AT+SOCKA?
AT+SOCKAEN?
AT+SOCKASL?

AT+WKMOD="NET"
AT+SOCKA="TCP","198.51.100.73",34827
AT+SOCKAEN="on"
AT+SOCKASL="long"
AT+S

Ожидание перезапуска и повторный вход

AT+WKMOD?
AT+SOCKA?
AT+SOCKAEN?
AT+SOCKASL?
AT+ENTM

After each line the program waits for confirmation. If the parameters already match, only read and exit are used. If the change fails, saving is prohibited. After AT+S additional AT+Z the configurator does not send: saving according to the directory already causes a restart.

10.5. How to understand the diagnosis

UART. Answer of the form +UART:115200,"NONE",8,1,"RS485" means baud rate 115200, no parity, 8 data bits, 1 stop bit and flow control value RS485. The last field does not mean that the computer is connected specifically to the RS-485 connector. The tester shows this value, but does not change it. The local form does not offer flow control.

IMEI and ICCID. A normally read IMEI identifies the modem. ICCID confirms SIM data reading, but does not verify balance, network registration or Internet access service. Do not publish these identifiers in public reports.

RSSI. The tester uses the following interpretation:

RSSI Tester rating Action
0–9 Failure: critically weak signal Check antenna and coverage
10–19 Warning: weak signal Assess stability and improve reception
20–31 Verification successful Continue IP and TCP diagnostics
99 Signal not defined Check boot, SIM, antenna and network

For normal RSSI values, the tester displays an approximate level −113 + 2 × RSSI dBm. For example, RSSI 23 corresponds to approximately −67 dBm. BER - second parameter CSQ; a value of 99 means undefined/unknown. The tester outputs BER without separately assessing link suitability.

Local IP. AT+CIP? shows the address from the mobile network. It may be private and does not have to match the external address visible to the server due to the NAT operator. The presence of a non-zero IPv4 does not mean a connection with the desired TCP server.

SOCKALK. Connected — confirmation of the live state of Socket A at the time of the request. Disconnected — the connection was not established at that moment. This request does not check whether the server understands your instrument's messages.

10.6. Operator service commands

The following commands are provided to help you understand the modem's capabilities. The project's two applications do not provide buttons to execute them. Changes to UART, APN and service packets are performed in a separate service script with pre-agreed parameters.

Task Command Peculiarity
Get help AT+H Modem Help
Find out the serial number AT+SN? Device information
Check echo AT+E? Shows whether the modem repeats the entered commands
Read APN AT+APN? The full answer contains the username and password; do not include it openly in the report
Set APN AT+APN="<APN>","<логин>","<пароль>" The values ​​are taken from the operator; this is a settings change
Read UART AT+UART? Lock the entire set of parameters before changing
Set UART AT+UART=<скорость>,"<чётность>",<биты>,<стоп>,"<flow>" After application, you may need to reopen the port with new parameters
Find out auto restart AT+RSTIM? Restart interval when there is no network data
Check ICMP address AT+PING="<DNS/IP>" Additional accessibility check; does not replace the TCP port test
Restart AT+Z Breaks the current exchange; does not replace saving AT+S
Save changes AT+S Executed after successful responses to all changes; restarts the modem

The full syntax and limitations of service functions depend on the firmware version. Do not automatically transfer APN, password and server values ​​from other people's examples. Translated knowledge base materials contain design errors; The correct ASCII command names are given in the original AT manual.

10.7. Answers and time limits

OK or +OK confirm the completion of the command. ERROR, +ERR..., +CME ERROR... mean refusal. In the model reference book, code 58 indicates an incorrect command/format, code 3 indicates an incorrect type or missing parameter. Keep the actual answer in its entirety: error options depend on the firmware.

A typical AT response is expected to take up to 3 seconds and is limited to 4096 bytes. After saving, the configurator waits 4 seconds and makes up to three login attempts. These are technical limits of the program, and not a guaranteed time for SIM registration on the network. If the connection has not yet been established, repeat the diagnostics later.

The tester sending context is set to 5 seconds. It is not a server response timeout and does not guarantee that the write system call will abort after exactly 5 seconds. The wait for the application response is determined by your protocol and log monitoring.

11. How to evaluate the test result

Level Which confirms What is checked
Local connection The computer communicates with the modem Successfully login to AT and read version
Configuration Selected settings saved Control reading of the configurator
Mobile network Received non-zero local IP Line CIP; evaluate together with SIM and signal
TCP Socket A is connected to the expected server SOCKA, SOCKAEN, SOCKALK and server log
Data transmission The program wrote bytes to the COM port Arrow → and number of bytes
Through delivery The server received the required bytes Server reception log
Application protocol The server understood the request and returned the correct response Response content and protocol rules

For a text experience, it's convenient to use a unique string, like TEST-MODEM-001, and a consistent ending. First compare the exact text and delimiter bytes on the server, then send the response ACK-MODEM-001 via the same connection. This is an example of a test agreement; The modem does not create such a response automatically.

To complete the test, record the firmware version, COM port, UART, Socket A status, transmission time, server receive and return response. Consider the device verified by the levels actually completed, and not by one green line.

12. Sources and illustrations from the knowledge base

During preparation, a section of the knowledge base was used gprs232-730:

Material What's used
“User Manual USR-GPRS232-730 - Russian edition 2025” Connection, purpose of interfaces, transmission diagram and modes
"AT commands USR-GPRS232-730/734 V1.0.0" Command names and purposes, syntax, saving and restarting
"USR-GPRS232-730 Quick Start Guide" Sequence of preparation and verification of exchange

The illustrations of the equipment in section 8 correspond to the attachments of the Russian edition in the knowledge base. To allow the guide to open locally without logging into the panel, the figures are exported from the same original PDF to images/knowledge-base/. The attachments and files correspondence table is located in description of image sources.

Snapshots of our two apps are in images/ and are included in sections 3–4. They show the project interface; Manufacturer's diagrams explain the equipment. User IPs, ports and IDs in the snapshots are closed.

Original local documentation: Russian edition 2025 And AT Directory V1.0.0.

EXCHANGE PROTOCOL

Every step
confirmed

Serial AT commands.
Check before saving.

+++ → a → a → +ok
AT+VER?
AT+WKMOD?
AT+SOCKA?
AT+SOCKAEN?
AT+SOCKASL?
OK

Check before saving

The configurator changes different parameters. A change error stops the chain up to AT+S.

AT+S saves the configuration and restarts the modem. The application then reads the four parameters again and exits via AT+ENTM.

Regular commands end with a CR. Transparent exchange works after returning to work mode.

AT Command Reference All 67 model commands

AT command directory USR-GPRS232-730/734

Purpose, application and boundaries of automation in two project programs

This guide complements user manual. It contains all 67 positions of the AT-directory V1.0.0 with a Russian description. The syntax of commands that execute project applications is detailed in section 10 of the user manual. For the remaining functions, the purpose below is given, and not a universal scenario for reconfiguring equipment.

Sources: knowledge base article "AT commands USR-GPRS232-730/734 V1.0.0", ID e22ebd11-8c51-4e03-85ac-60f67bee3e3c, And original PDF. Command names are checked against the original: machine translations can turn Latin abbreviations into Cyrillic and distort examples.

Operating rules

  • Entering command mode: pause, +++ without ending, get a, hand over a without ending, get +ok.
  • Regular AT commands fail CR (0x0D). After each command, wait for a complete response with OK or errors.
  • A parameter request usually takes the form AT+NAME?, record - AT+NAME=..., list of acceptable values ​​- AT+NAME=?, if provided by a specific command.
  • Don't attribute ? or = to executive teams automatically. For example, saving is done as AT+S.
  • Parameters are passed with ASCII quotes ". In examples <...> denotes the value to be substituted, not the text to be copied.
  • The project tester reads and returns to operating mode; four target parameters are configured and saved by the configurator.
  • Service changes to APN, UART, and other sockets and packages require a separate operator decision. After changing, check OK, perform the prescribed save and test read.

1. Device management and command access

№ Command Description Application in the project
1 AT+H Modem help output Manual service check
2 AT+Z Restarting the modem Programs do not automatically send
3 AT+E Read/set echo AT commands; on includes, off turns off Programs take possible echoes into account when parsing
4 AT+ENTM Returning from AT mode to operating mode Both programs
5 AT+WKMOD Read/Select Mode CMD, SMS, NET, HTTPD Both read; the configurator selects NET
6 AT+CALEN Enable/disable the ringer function Doesn't change
7 AT+NATEN Allowing AT commands over the network Doesn't change
8 AT+UATEN Allowing serial AT commands in transparent mode Doesn't change
9 AT+CMDPW Command password Unreadable and unchangeable
10 AT+CACHEN Enabling/disabling data caching Doesn't change
11 AT+STMSG Modem start message issued after switching on Doesn't change
12 AT+RSTIM Automatic restart interval when there is no network data; 0 disables this feature Doesn't change

AT+E controls the local echo of commands rather than the replay of application messages by the TCP server. AT+NATEN And AT+UATEN refer to alternative command access methods and are not our application buttons.

In the original directory RSTIM has a default value of 1800 seconds. If the connection cyclically drops after about 30 minutes of no traffic, this setting needs to be checked along with the server log. Disabling the timer is a recovery policy change, not a universal fix.

2. Save and restore

№ Command Description Consequence
13 AT+S Saving current settings Restarts the modem; the configurator executes only after confirmed changes
14 AT+RELD Restoring a user's default preset Changes the configuration and restarts the device
15 AT+CLEAR Restoring factory configuration Resets settings and restarts the device
16 AT+CFGTF Saving current settings as a user default set Changes the set it returns to RELD

Restoring custom and factory settings are different operations. AT+CLEAR And AT+RELD are not used by the configurator or tester and are not needed for normal testing of Socket A. Before recovery, you need to know how to return the APN, UART, server address and service installation parameters.

3. Device and SIM card information

№ Command Description What can be concluded
17 AT+VER Firmware version Needed to compare behavior with the directory
18 AT+SN Serial number Instance identification
19 AT+ICCID ICCID of installed SIM The modem read the SIM ID
20 AT+IMEI Modem IMEI GSM module identification
21 AT+CNUM SIM phone number, if available to the device Number availability is not guaranteed for every SIM

The tester automatically uses VER, ICCID And IMEI. None of these requests check the balance or tariff activity. Hide IMEI, ICCID and phone number before publishing the report.

4. Serial interface and APN

№ Command Description Peculiarity
22 AT+UART Speed, parity, data bits, stop bits, flow control The tester reads; the change may require re-opening the COM port
23 AT+RFCEN Enabling the RFC2217 feature Scenario for remote control of the serial interface; the project does not configure
24 AT+APN APN, operator network username and password The tester reads and hides the login/password in the report

UART format: AT+UART=<baud>,"<parity>",<data>,<stop>,"<flow>". The reference book lists the parities NONE, ODD, EVEN, 7/8 bits, 1/2 stop bits; Check the acceptable flow control values ​​using the response from your firmware. Application local UART fields are not sent AT+UART=....

APN Format: AT+APN="<APN>","<имя>","<пароль>". Check with your operator to see if a username/password is required and how your firmware accepts empty fields. Someone else's APN example is not the appropriate setting for your SIM card.

5. Sockets and network status

№ Command Purpose
25 AT+SOCKA Protocol, address and port Socket A; the configurator writes the target TCP server
26 AT+SOCKB Protocol, address and port Socket B
27 AT+SOCKC Protocol, address and Socket C port, if supported by model/firmware
28 AT+SOCKD Protocol, address and port Socket D, if supported by model/firmware
29 AT+SOCKAEN Enable Socket A; target value of the project - on
30 AT+SOCKBEN Enabling Socket B
31 AT+SOCKCEN Enabling Socket C
32 AT+SOCKDEN Enabling Socket D
33 AT+SOCKASL TCP Connection Type A: long or short; project chooses long
34 AT+SOCKBSL TCP connection type B
35 AT+SOCKCSL TCP connection type C
36 AT+SOCKDSL TCP connection type D
37 AT+SOCKALK Current state of connection A; tester requests AT+SOCKALK?
38 AT+SOCKBLK Current state of connection B
39 AT+SOCKCLK Current state of connection C
40 AT+SOCKDLK Current state of connection D
41 AT+SOCKRSTIM Restart timer for fatal network connection failure
42 AT+SHORTIM Timer related to short connection; Please check the firmware for applicability and semantics
43 AT+SOCKIDEN Allow socket ID to be displayed in data
44 AT+CIP Local IP addresses of connections; tester uses AT+CIP?
45 AT+PING Checking the availability of the specified DNS/IP using a modem
46 AT+CSQ GSM signal quality: RSSI and BER

Server format: AT+SOCKA="TCP","<DNS/IPv4>",<порт>. In the directory, the address is limited to 100 bytes, the port is limited to the range 1–65535. Responses are used for the state Connected And Disconnected.

Items C/D are present in the general directory 730/734. The Russian 730 manual describes two A/B connections, so the presence of C/D in the catalog is not a promise that your device will support these sockets. Project programs work only with A.

In the original paragraph 41 the heading is written SOCKRSTM, and formats and example - SOCKRSTIM. In paragraphs 41–43 there are also mixed up query and description lines in the pivot table. Therefore, these timers are listed here with reservations, without a ready-made change script. Our apps don't send them.

PING does not check the TCP application port. The server may accept TCP and not respond to ICMP, or respond to ICMP while the desired port is closed. CIP And PING in the reference book they are marked as functions of firmware V3.0.0 and later.

6. Registration packages

№ Command Purpose
47 AT+REGEN Enable registration package
48 AT+REGTP Content selection: ICCID, IMEI, registration ID or user data
49 AT+REGID Registration ID value
50 AT+REGDT Registration package user data in hexadecimal notation
51 AT+REGSND When to send the packet: upon connection (link), with data (data) or both options (link&data)

The registration package may appear on the server before the first user message. The format must match the server protocol. Automatically adding a packet to each data block changes what the server receives compared to the text of the Message field.

7. Heartbeat

№ Command Purpose
52 AT+HEARTEN Enable/disable periodic heartbeat packet
53 AT+HEARTDT Heartbeat content in hex format
54 AT+HEARTTP Package direction: COM or NET
55 AT+HEARTTM Packet sending interval

Heartbeat can help detect breaks and maintain traffic, but does not itself guarantee the health of the application server. If selected COM, the tester can receive data without the remote application responding. The two project programs do not change these parameters.

8. HTTPD client

№ Command Purpose
56 AT+HTPTP Selecting HTTP request method: GET or POST
57 AT+HTPURL Request Path/URL
58 AT+HTPSV HTTP server address and port
59 AT+HTPHD HTTP headers
60 AT+HTPPK Filtering HTTP headers in transmitted data
61 AT+HTPTIM HTTP script timeout

This block refers to the mode HTTPD, and not to the target mode NET. The project configurator switches the device to transparent TCP. The listed HTTP commands do not mean the presence of TLS/HTTPS and do not turn the modem into an HTTP server.

9. SMS, cloud and location

№ Command Purpose
62 AT+DSTNUM Recipient's phone number for SMS scenario
63 AT+SMSEND Send SMS with number, encoding type and content
64 AT+CLOUDEN Enable transparent sharing via USR cloud
65 AT+CLOUDID Device ID in cloud scenario
66 AT+CLOUDPA Cloud connection password
67 AT+LBS Base station information including LAC/CID

SMS control and transparent AT commands over the network are separate ways to control the modem. There are examples in the manuals with a command password prefix. They cannot be considered ready for every device: the password and permissions may vary. The two programs in the project only use the local COM port and do not send SMS.

LBS returns data to the base station; These are not GPS coordinates or a built-in map. Check the SMS encoding format and cloud parameters in the source directory and firmware. Message Tester is not an SMS or cloud client.

What to remember for the operator

For normal configuration, the configurator forms are sufficient. For testing - diagnostics of the tester and two-way communication with control on the server. Manual commands are useful when troubleshooting a problem, but you cannot mix them with an active application session: close the local port in the program before opening the service terminal.

If the request returns an error or is not confirmed, do not continue the save chain. Record the response and device status. After any save, check the actual values ​​by reading them again and check the network connection separately.

READY-TO-RUN BUILDS

Your instrument.
Your platform.

56 binaries for 28 OS and architecture combinations.
Select a configurator and tester for your system.

28 platforms

Cross compilation confirmed. Hardware testing for each platform is unconfirmed. amd64 is a regular 64-bit Intel/AMD system. The documentation describes the current code, the binary version is indicated in the release record.

Android arm64

build-e3225225c5a1 · 2026-11-28

Configurator ↓ 3.6 MB
SHA-256 and verification8244b51ddd8fae16d6440058e01925e67d2d1508a9e5befcb0ad587a67ccd74d

Cross assembly. Device testing has not been confirmed for this platform.

Tester ↓ 3.8 MB
SHA-256 and verification070b515b8673b6a06a0ed240c721003b8f5f82856a5f7056bfb95f4e5f62988d

Cross assembly. Device testing has not been confirmed for this platform.

Terminal ELF ARM64. You need a terminal and OS access to the serial device.

macOS amd64

build-e3225225c5a1 · 2026-11-28

Configurator ↓ 3.6 MB
SHA-256 and verification9f94194a063de453f73c2165b668277da469b4b235f3f018600864dac6fedc64

Cross assembly. Device testing has not been confirmed for this platform.

Tester ↓ 3.6 MB
SHA-256 and verificationae55fdc53f9cf348dfe67483eb971e4dcf3241e14459e423cff8616ab6a37828

Cross assembly. Device testing has not been confirmed for this platform.

macOS arm64

build-e3225225c5a1 · 2026-11-28

Configurator ↓ 3.4 MB
SHA-256 and verification2ad46dedfd70d34c262fa8fd0ad10e69d1c677823fba0e4a786cf19961ae6d33

Cross assembly. Device testing has not been confirmed for this platform.

Tester ↓ 3.4 MB
SHA-256 and verificationea5fc93c9f9b6c1f250b7f12bc0a686be7128be514edf9c53fe23d318099359f

Cross assembly. Device testing has not been confirmed for this platform.

FreeBSD 386

build-e3225225c5a1 · 2026-11-28

Configurator ↓ 3.1 MB
SHA-256 and verification9e3be3321cb57399bb4c57e1f2389a6964993c6976cd3d17f6273eeac3a2c908

Cross assembly. Device testing has not been confirmed for this platform.

Tester ↓ 3.1 MB
SHA-256 and verification6728f74c769169f053c41cd3c0c7e984fad674e10d4a728ffe3bee10e6dce644

Cross assembly. Device testing has not been confirmed for this platform.

FreeBSD amd64

build-e3225225c5a1 · 2026-11-28

Configurator ↓ 3.5 MB
SHA-256 and verificationd960b01af3697af1e89898ed848ebe29d057a8ef518e244aa3908885ab2193ec

Cross assembly. Device testing has not been confirmed for this platform.

Tester ↓ 3.5 MB
SHA-256 and verification039c5b0c66646d432c3df0aff4f985271db4c711727680b45764b5c27bc8f86a

Cross assembly. Device testing has not been confirmed for this platform.

FreeBSD arm

build-e3225225c5a1 · 2026-11-28

Configurator ↓ 3.2 MB
SHA-256 and verificationa66d8c69f8f95517e74253eda611cb030e9ea4f2d224993b4faf34fc936ad4cc

Cross assembly. Device testing has not been confirmed for this platform.

Tester ↓ 3.2 MB
SHA-256 and verification39517f6ee8c75abe999f5a22b760efb7909f319a56044ffb436f24c3bdf394aa

Cross assembly. Device testing has not been confirmed for this platform.

FreeBSD arm64

build-e3225225c5a1 · 2026-11-28

Configurator ↓ 3.4 MB
SHA-256 and verification121d5a050ddaaacc5beb82d203e9995bf36f81fff4971f651c25ca47eeb9f4a8

Cross assembly. Device testing has not been confirmed for this platform.

Tester ↓ 3.4 MB
SHA-256 and verification2062d899077b3de51a7c7d1a0ab954eab7449b8627152f6168a1f95064c16bef

Cross assembly. Device testing has not been confirmed for this platform.

Linux 386

build-e3225225c5a1 · 2026-11-28

Configurator ↓ 3.2 MB
SHA-256 and verification7b939720ea0f31c72c85e87550d3b6a725bf175b54c3dc913a326bb686d087ba

Cross assembly. Device testing has not been confirmed for this platform.

Tester ↓ 3.2 MB
SHA-256 and verificationb4fadc2ce192336c69ced5bf3e25e4051d65ab1a42abc58a5499e69b5bfb5d26

Cross assembly. Device testing has not been confirmed for this platform.

Linux amd64

build-e3225225c5a1 · 2026-11-28

Configurator ↓ 3.6 MB
SHA-256 and verification121a1e006eb0ce9c62e063059cf391e196cb8bd3a47475143b8bff8d2de5a2f6

Cross assembly. Device testing has not been confirmed for this platform.

Tester ↓ 3.6 MB
SHA-256 and verificationfb0be71c1be4a47367260ac885e80123d7cda46a90ee5c18c07ce348f71e9a44

Cross assembly. Device testing has not been confirmed for this platform.

Linux arm

build-e3225225c5a1 · 2026-11-28

Configurator ↓ 3.3 MB
SHA-256 and verification45c5ae681d72f5843f78a293477c81e5b230f22c020e7e3498fc3298be685186

Cross assembly. Device testing has not been confirmed for this platform.

Tester ↓ 3.3 MB
SHA-256 and verification3819d9d8225c3d80c586a0ba4bffb338c1e6326d598aaf783a4b4e524f4f92ce

Cross assembly. Device testing has not been confirmed for this platform.

Linux arm64

build-e3225225c5a1 · 2026-11-28

Configurator ↓ 3.4 MB
SHA-256 and verification5835cf938c1f8deb799937dfc97be7e864d75b2ba73d3085d46cb72d6a8078f0

Cross assembly. Device testing has not been confirmed for this platform.

Tester ↓ 3.5 MB
SHA-256 and verification0dfed388e89c212b762ea710d00b85a982f8b3ada880873495e40c93eea7cc41

Cross assembly. Device testing has not been confirmed for this platform.

Linux loong64

build-e3225225c5a1 · 2026-11-28

Configurator ↓ 3.6 MB
SHA-256 and verification165d81ce3b970e380676e5b35917818ccd63abee1f5ba6b11a8c407e7d823a19

Cross assembly. Device testing has not been confirmed for this platform.

Tester ↓ 3.6 MB
SHA-256 and verification352da40294f26f87fe0e16fde5d0f136c40e0d3baaf1e911bc1cc4005b31678f

Cross assembly. Device testing has not been confirmed for this platform.

Linux mips

build-e3225225c5a1 · 2026-11-28

Configurator ↓ 3.7 MB
SHA-256 and verification1c970fe43136786c73b7bb8198dbefdf873a1a0af0d98581fe02d35e3f36ce88

Cross assembly. Device testing has not been confirmed for this platform.

Tester ↓ 3.8 MB
SHA-256 and verification51afd13ab1fc022dcd1c7e55af7c1eeb69d332fbb2158012d46a3c2d30c614b4

Cross assembly. Device testing has not been confirmed for this platform.

Linux mips64

build-e3225225c5a1 · 2026-11-28

Configurator ↓ 3.9 MB
SHA-256 and verification0a8a1359ba11bda145a49aedad8d03f21d970aa5685a4010cd665771299b3f2f

Cross assembly. Device testing has not been confirmed for this platform.

Tester ↓ 4.0 MB
SHA-256 and verification7db9e7892a91faa335695aa5b93e238d449a92d3bff918f5260da6700b603b6c

Cross assembly. Device testing has not been confirmed for this platform.

Linux mips64le

build-e3225225c5a1 · 2026-11-28

Configurator ↓ 3.9 MB
SHA-256 and verificatione7901b04bc70f7a589822a7fe118304f753586ec56d8bb891389d4dff68ae588

Cross assembly. Device testing has not been confirmed for this platform.

Tester ↓ 4.0 MB
SHA-256 and verificationa9311567b8e1ce78bcbcbada89f597dd5d61f9819caa7ed499c303bba511d055

Cross assembly. Device testing has not been confirmed for this platform.

Linux mipsle

build-e3225225c5a1 · 2026-11-28

Configurator ↓ 3.7 MB
SHA-256 and verification933e2b155235e7f5f8cc7a7df940d30a737aa0ed922fbd498957f8fce4f24d5c

Cross assembly. Device testing has not been confirmed for this platform.

Tester ↓ 3.8 MB
SHA-256 and verification7beedbceb2a1fd98423da38f6cbf16c3d098d2d34b5bf31c7021aa64cbf7eeae

Cross assembly. Device testing has not been confirmed for this platform.

Linux ppc64le

build-e3225225c5a1 · 2026-11-28

Configurator ↓ 3.6 MB
SHA-256 and verification11fc2f6a9c70845d4a3b4ed5a719ead3a132a604ce826fee63cdc5a5e41c5683

Cross assembly. Device testing has not been confirmed for this platform.

Tester ↓ 3.7 MB
SHA-256 and verification1c95d1b31e620aaf350c051a33789128a7e5217d3259eb5a6a59bbc0fb59d55b

Cross assembly. Device testing has not been confirmed for this platform.

Linux riscv64

build-e3225225c5a1 · 2026-11-28

Configurator ↓ 3.3 MB
SHA-256 and verificationa5229aef137799377269a10b8a35ea3441222191cd6a3559fc470dad23dcf03c

Cross assembly. Device testing has not been confirmed for this platform.

Tester ↓ 3.3 MB
SHA-256 and verification707c50f00fdfe361830eb85331a23b460f570cc32663e127d841c313a098ecc7

Cross assembly. Device testing has not been confirmed for this platform.

Linux s390x

build-e3225225c5a1 · 2026-11-28

Configurator ↓ 3.8 MB
SHA-256 and verification4d0bb291ddeedb744b9f04112410f7491d3ccb587154d285e590415f40273bc4

Cross assembly. Device testing has not been confirmed for this platform.

Tester ↓ 3.8 MB
SHA-256 and verificationc20f0c2e466c6491224d757630c1e7b6544488cf517ec44ef628bb0017a5f59b

Cross assembly. Device testing has not been confirmed for this platform.

OpenBSD 386

build-e3225225c5a1 · 2026-11-28

Configurator ↓ 3.1 MB
SHA-256 and verification2e5b97f86375481474f4c5ca147c5e4a43f4668ad8c904ba12b8889b4888fb5b

Cross assembly. Device testing has not been confirmed for this platform.

Tester ↓ 3.1 MB
SHA-256 and verification690cb8fea8b6ed271a511df539cebf9cf550a084352c9dcf3869c654084c0922

Cross assembly. Device testing has not been confirmed for this platform.

OpenBSD amd64

build-e3225225c5a1 · 2026-11-28

Configurator ↓ 3.5 MB
SHA-256 and verification03477ce707750335e52fdb208249e6454d8afe467ab7bb7d1e69f3892db7ca0b

Cross assembly. Device testing has not been confirmed for this platform.

Tester ↓ 3.5 MB
SHA-256 and verificationc7af940c53cf26ca904be9deb556671d880e4de5813be6fdc5128926888bbf98

Cross assembly. Device testing has not been confirmed for this platform.

OpenBSD arm

build-e3225225c5a1 · 2026-11-28

Configurator ↓ 3.2 MB
SHA-256 and verificationfaeb43c457154c7bbafdfbb99bfb1f4d9207ac088df6117cdf35f9f8acea6071

Cross assembly. Device testing has not been confirmed for this platform.

Tester ↓ 3.3 MB
SHA-256 and verificationa13738aec25b5b8a9f25c33ac7392739e88d22886524f53ea183c9ae5521d319

Cross assembly. Device testing has not been confirmed for this platform.

OpenBSD arm64

build-e3225225c5a1 · 2026-11-28

Configurator ↓ 3.4 MB
SHA-256 and verification35f1c39295c5d0c4d0dbae1b91c364a59d32a27c69009fb7f3195e67908404b1

Cross assembly. Device testing has not been confirmed for this platform.

Tester ↓ 3.4 MB
SHA-256 and verification59d9cec5bb7b3d49da5a77ab3f7c7bdd68c03d5adf5ca8f9dc3d888ada763ba9

Cross assembly. Device testing has not been confirmed for this platform.

OpenBSD ppc64

build-e3225225c5a1 · 2026-11-28

Configurator ↓ 3.5 MB
SHA-256 and verificationd23c2a4fbe20318d3f7899085749a2625a37daba47937494a1fa3b49b39eb135

Cross assembly. Device testing has not been confirmed for this platform.

Tester ↓ 3.6 MB
SHA-256 and verification748e2abac7a230ac9eb4d56f37c12ceb3b78e86cb87d88f77819d028812fad83

Cross assembly. Device testing has not been confirmed for this platform.

OpenBSD riscv64

build-e3225225c5a1 · 2026-11-28

Configurator ↓ 3.2 MB
SHA-256 and verification9b602e1120eeebe1cc321917d25e419fb9c477bb30a0f4eddb2ff09d42807330

Cross assembly. Device testing has not been confirmed for this platform.

Tester ↓ 3.3 MB
SHA-256 and verification9d4f9b6a2372bb2e7ddb87532623b54c1739747ba3205ba8991fa46a0d6f428b

Cross assembly. Device testing has not been confirmed for this platform.

Windows 386

build-e3225225c5a1 · 2026-11-28

Tester ↓ 3.1 MB
SHA-256 and verificationba0e8004916b7436ced4d48cfd911a858a0ff5104925302ebfb6f3a9e4e22d1e

Cross assembly. Device testing has not been confirmed for this platform.

Configurator ↓ 3.0 MB
SHA-256 and verification5b4150d75b2c3f6b7cf27f6a9ef7c6d3f85f0d06d64edb0841b1c8d59e6101cc

Cross assembly. Device testing has not been confirmed for this platform.

Windows amd64

build-51848a59eb02 · 2026-11-28

Tester ↓ 3.5 MB
SHA-256 and verification7ac80f59f9d352efb15c21481377db6b9e9605cca0efb78aa4958d27e485932f

Cross assembly. Device testing has not been confirmed for this platform.

Configurator ↓ 3.4 MB
SHA-256 and verificationc41144f362c69867dd19e3a8699994fa6265a60274902263a874c5ef7fbe9524

Cross assembly. Device testing has not been confirmed for this platform.

Windows arm64

build-51848a59eb02 · 2026-11-28

Tester ↓ 3.2 MB
SHA-256 and verification5dd48e044a9cc3b32a3030a4ccac81f5e9681b09326dafd71d1f7aa2f97b645b

Cross assembly. Device testing has not been confirmed for this platform.

Configurator ↓ 3.2 MB
SHA-256 and verification87b99de695322f3436c6cb8e041d3865b6ad0cbcf6175676f725c75b41fffab4

Cross assembly. Device testing has not been confirmed for this platform.

SUPPORT

If the connection
not installed.

Port busy or not found

Close other programs, check the USB-RS-232 driver and port number. On Linux, check your permissions. Refresh the list or enter the name manually.

Modem is not responding

Check the actual UART, power and RS-232 cable. The form values ​​must match the current modem configuration.

Socket A shows Disconnected

Check SIM, APN, signal, server availability and firewall. Wait for registration on the network and repeat the diagnostics.

Settings saved, but no response

Check the connection and bytes on the server. Agree on CR/LF/CRLF and application protocol.

Save not confirmed

Restart the modem and read the parameters again. If there was an error, some of the values ​​could have changed in RAM before saving.

MANUFACTURER MATERIALS

Original
PUSR documents.

Directories and proprietary utilities.
Downloads from official resources.

USR-GPRS232-730 - PUSR equipment. Photos and diagrams from the Russian edition of the 2025 manual. Application screenshots are anonymized. Check the device version and the document version.

Russian DOCX instructions · application screenshots are in Russian